ATV58 MANUAL PDF

The ALTIVAR 58 (ATV58) family of adjustable frequency AC drive controllers is all the parameters detailed in this manual will be accessible if a drive controller. User’s Manual for the Altivar 58F and for the I/O . 1 Follow the recommendations in the User’s Manual supplied with the speed controller, most importantly. ALTIVARĀ® 58 (ATV58) AC drive controllers offer superior performance in a compact .. A GV2 manual motor starter, ATV58 drive controller, and an output.

Author: Yozshular Faezil
Country: South Sudan
Language: English (Spanish)
Genre: Politics
Published (Last): 11 January 2017
Pages: 338
PDF File Size: 9.47 Mb
ePub File Size: 19.80 Mb
ISBN: 497-9-36420-202-3
Downloads: 36237
Price: Free* [*Free Regsitration Required]
Uploader: Gujar

The speed controller status can be modified by sending a control aatv58 CMD or by the occurrence of an event example: The commands are combinations of the 5 mandatory bits. Their description can in no way beconsidered contractual.

User’s manual FIPIO ATV58 : VW3A | Schneider Electric

In local forcing all write requests from the fieldbus are refused. The bits in the control register CMD have the following meaning: The local forcing output must be monitored, as line control is restored at the current chart step at the moment of interrupt caused by local forcing.

The bus controlling the speed controller can relinquish control by setting bits 8 and 15 of the control word CMD to 1. These documents should be referred to for hardware and software setup as well as for any variables specific to each bus. The speed controller status is given by the value of the status register ETA.

  FUERZA DEL SHECCID PDF

The fieldbus connected to the communication maual always takes priority.

Atv58 manual – sednkww

We also recommend consulting one of the Altivar 58 programming guides for additional manyal operation, factory settings, etc. For safety reasons its use must be restricted to the debug phase. Each state represents an aspect of the internal behaviour of the speed controller.

The products described in this document may be changed or modified at any time, either froma technical point of view or in the way they are operated. It comes with the specific documentation supplied with: However, the fieldbus which is ztv58 controlling the speed controller may send configuration words only when the motor is stopped or adjustments, and read signalling words.

Communication principle The Altivar 58 can be connected to manul fieldbuses: The chart below has been adapted to the characteristics of the Altivar 58 to facilitate programming.

The “Internal Variables” User’s manual defines the variable speed controller control process using the serial link as well as the internal variables for the speed controller which are common to the various types of bus. If a logic input assigned to the local force function is set to 1: DC injection stop H’F’: Type of at5v8 Corresponding Actions for restoring control Drivecom state of the Altivar 58 using the fieldbus Freewheel stop “ATV58 powered up” – set the logic input assigned to the “freewheel amnual function to 1 – perform the transitions required to return the speed controller to “run” status Fast stop “ATV58 running” – set av58 logic input assigned to the “fast stop” function to 1 DC injection stop “ATV58 running” – set the logic input assigned to the “injection stop” function to 1 Stop via keypad “ATV58 powered up” – release Stop key STOP key – perform the transitions required to return the speed controller to “run” status manuao control “ATV58 powered up” – set the logic input assigned to stop via logic input STOP to 1 STOP LI1 – perform the transitions required to return the speed controller to “run” status Local forcing:

  INTER CAETERA DIVINA 1493 PDF

admin